Impact Of Positive End Expiratory Pressure Device On Maximum Expiratory Pressure, Maximum Voluntary Ventilation And Dyspnea Index In Patients After Valvular Heart Surgery: Randomized Controlled Trial

Journal of Positive School Psychology • 2022
العودة
معلومات البحث
المؤلفون Mohamed Ibrahim Mabrouk, ELsayed Mehrem, Ahmed Barakat Bekheet, Roshdy Mohamed Kamel , Shymaa Mohamed Ali
الكلمات المفتاحية Not Available
المجلة العلمية Journal of Positive School Psychology
الناشر Gorakhpur India: ASR Research Center
المجلد 6
العدد 6
الصفحات 8186-8194
publication.type International
رابط البحث Open Link
المواد المرفقة Not Available
الملخص
Background
Rheumatic heart disease (RHD) is the most common cause of acquired heart disease in children and young adults globally In Egypt, the prevalence of RHD is still high and the use of devices and prosthetic materials is increasing dramatically.
So this experiment was conducted to investigate the efficacy of PEEP device on respiratory muscle strength in patients who underwent valve surgery.
Methods
Evaluation Procedure
1- Measurement of MEP: This is the most widely used noninvasive method in the clinic for evaluation of respiratory muscle strength (RMS) 13.
Steps of measuring: Respiratory pressure meter device:
CareFusion UK 232 Ltd, ME4 4QY.UK, SN: (064-02857) used to measure MEP.
1-The device is at zero and calibrated before each measurement.
2- The patient maximally exhales from TLC. Nose clips are required. The patient is coached to ensure adequate lip seal around the mouthpiece and achieve maximum voluntary effort, and the effort is repeated until at least three measurements have