Thermal regulation for buildings using evaporative cooling technique: Experimental study.
Case Studies in Thermal Engineering • 2024
معلومات البحث
المؤلفون
Abdullah Alrashidi, Saber Abdo, MA Abdelrahman, Ahmed A Altohamy, Ismail MM Elsemary
الكلمات المفتاحية
Passive coolingActivated aluminaThermal loadEvaporationEnvironmental analysis
المجلة العلمية
Case Studies in Thermal Engineering
الناشر
elsevier
المجلد
61
العدد
September 2024, 104891
الصفحات
Not Available
publication.type
International
رابط البحث
Open Link
المواد المرفقة
Not Available
الملخص
Global warming and increased air-conditioning demand drive up energy use. A passive cooling system for the building's roofs is one solution to this problem. The current study intends to provide a unique evaporative cooling concept for cooling building roofs that use significantly less water than prior approaches. To reduce room temperature, saturated-activated alumina beds with 2, 4, and 6 cm thicknesses were put over the roof. Pure and 35 PPT saline water were utilised to evaluate system performance and sustainability. The device successfully reduced rooftop temperatures by 84 % and 70.9 % after 24 h of testing (6 h during daytime and 18 h at night) under heat loads of 800 and 1000 W/m2. The findings show that salt water is a feasible alternative to freshwater that does not sacrifice cooling efficiency. From an environmental standpoint, compared to a bare roof, a 6-cm layer of saturated activated alumina tables can reduce annual carbon dioxide emissions by 71.3 tCO2/m2 and 92 tCO2/m2 for roof areas subjected to daily solar radiation of 6000 W h/day and 4800 W h/day, respectively.