Ahmed Shawky Mohamed Awaad Mohamed Soliman
Lecturer
Investigation of using sill under gate as a scour countermeasure downstream of a sluice gate
The Egyptian International Journal of Engineering Sciences and Technology • 2023
Publication Information
Authors
Elsayed M.Elshahat , Ahmed Sh. Awwad
Keywords
Experimental work; maximum relative scour depth; sill; sluice gate.
Journal
The Egyptian International Journal of Engineering Sciences and Technology
Publisher
Not Available
Volume
43
Issue
1
Pages
74-80
publication.type
Local
Paper Link
Not Available
Supplementary Materials
Not Available
Abstract
Scour is a natural phenomenon caused by the removal of soil from bed caused by a stream's erosion, which happens around or next to moving water structures. Various studies have been conducted to understand better local scour events in order to construct hydraulic structures safely and economically. This paper investigated the use of a sill under the gate and its effect on the maximum scour depth downstream of a sluice gate. The experiments were performed at different relative sill heights (hs/Ls = without sill, 3.8, 8.0, 12.0, and 15.0%), and with various relative gate openings (a/Ls) of 13%, 18%, and 23%. The results revealed the effectiveness of the sill under the gate in decreasing the maximum scour depth. All sill heights reduced the maximum scour depth downstream of the sluice gate. The relative sill height of 8% gave the minimum value of the maximum relative scour depth for all relative gate openings. The results of this study can be used in the design considerations for gates and their protection.