Mohammed Ahmed El Sayed Kassem
Professor
Nano-sized cadmium-benzothiazole Schiff base complexes: Synthesis, characterization, and the impact of surfactants for cadmium determination
Applied Organometallic Chemistry • 2023
Publication Information
Authors
41- Mohammed A. Kassem, Reem Kamal Shah
Keywords
cadmium (II), Nano-complexes, real samples, Schiff bases, spectrophotometry
Journal
Applied Organometallic Chemistry
Publisher
Wiely
Volume
Not Available
Issue
Not Available
Pages
Not Available
publication.type
International
Paper Link
Open Link
Supplementary Materials
Not Available
Abstract
In this paper, three benzothiazole-Schiff bases, 2-([benzothiazol-2-ylimino]
methyl)phenol (L1), 2-([benzothiazol-2-ylimino]methyl)-4-chlorophenol (L2),
and 2-([benzothiazol-2-ylimino]methyl)-4-bromophenol (L3), were environmentally
friendly prepared using a microwave assisted synthesis. These synthesized
ligands were used to chelate Cd (II) to produce three nano-sized solid
complexes, which were characterized using TEM, FT-IR, and XRD. Then three
developed spectrophotometric approaches for ultra-trace quantification of
divalent cadmium have been investigated and the sensitivity of these developed
methods was enhanced using micellar medium. The influence of the type
and amount of buffer, pH, type of surfactant, and amount of ligand during
quantification of cadmium ion were monitored and determined. The calibration
curve was valid over the concentration ranges of 1.0–9.0, 1.1–12.0, and
1.5–14.9 μg mL1 of Cd (II) with detection limits of 0.407, 0.313, and
0.453 μg mL1 using L1, L2, and L3, respectively. The described approaches
had been effectively applied for Cd (II) ion quantification in some water
samples.
methyl)phenol (L1), 2-([benzothiazol-2-ylimino]methyl)-4-chlorophenol (L2),
and 2-([benzothiazol-2-ylimino]methyl)-4-bromophenol (L3), were environmentally
friendly prepared using a microwave assisted synthesis. These synthesized
ligands were used to chelate Cd (II) to produce three nano-sized solid
complexes, which were characterized using TEM, FT-IR, and XRD. Then three
developed spectrophotometric approaches for ultra-trace quantification of
divalent cadmium have been investigated and the sensitivity of these developed
methods was enhanced using micellar medium. The influence of the type
and amount of buffer, pH, type of surfactant, and amount of ligand during
quantification of cadmium ion were monitored and determined. The calibration
curve was valid over the concentration ranges of 1.0–9.0, 1.1–12.0, and
1.5–14.9 μg mL1 of Cd (II) with detection limits of 0.407, 0.313, and
0.453 μg mL1 using L1, L2, and L3, respectively. The described approaches
had been effectively applied for Cd (II) ion quantification in some water
samples.
