Mostafa Abdel-mohimen Hussein
Lecturer
Development and performance evaluation of solar heating system for biogas production process
Case Studies in Thermal Engineering • 2022
Publication Information
Authors
Dawit Gudeta Gunjo, Vinod Kumar Yadav, Devendra Kumar Sinha, Ibrahim E. Elseesy, Gulam Mohammed Sayeed Ahmed, Mostafa A.H. Abdelmohimen
Keywords
Solar collector
Thermophilic microbes
CFD
Absorber plate
Thermal efficiency
Journal
Case Studies in Thermal Engineering
Publisher
Elsevier
Volume
39
Issue
Not Available
Pages
Not Available
publication.type
International
Paper Link
Open Link
Supplementary Materials
Not Available
Abstract
The breakdown of organic waste, through anaerobic digestion, is a temperature dependent process.
Attaining the temperature required for this process, under normal conditions, is a challenging
task. Hence, the development of an effective heating system is necessary. In this paper, a
solar heater’s computational fluid dynamics (CFD) model, with water as working fluid, is prepared
to estimate the temperatures of the absorber plate and that of the water available at the
outlet. The validations of the numerical results were done by conducting experimental trials and a
fair agreement between them was observed. For the examined solar collector, with outlet temperature
of 61◦C, the maximum thermal efficiency was estimated as 71%. The effects of operating
parameters (like transmissivity coefficient, ambient temperature, wind speed, inlet water temperature
and sun’s insolation), were explored. It was predicted that 30–60◦C tank water temperature
can be attained at flow rates of 0.00833, 0.0167, and 0.021 kg/s. The bent-tube Flat
Plate Colector (FPC) model, proposed in the present work, increases the residence time of water in
the collector. It also increases the outlet temperature. Hence, the developed FPC model may be
considered as an alternative solution for growing thermophilic bacteria during the anaerobic
digestion in biogas production.
Attaining the temperature required for this process, under normal conditions, is a challenging
task. Hence, the development of an effective heating system is necessary. In this paper, a
solar heater’s computational fluid dynamics (CFD) model, with water as working fluid, is prepared
to estimate the temperatures of the absorber plate and that of the water available at the
outlet. The validations of the numerical results were done by conducting experimental trials and a
fair agreement between them was observed. For the examined solar collector, with outlet temperature
of 61◦C, the maximum thermal efficiency was estimated as 71%. The effects of operating
parameters (like transmissivity coefficient, ambient temperature, wind speed, inlet water temperature
and sun’s insolation), were explored. It was predicted that 30–60◦C tank water temperature
can be attained at flow rates of 0.00833, 0.0167, and 0.021 kg/s. The bent-tube Flat
Plate Colector (FPC) model, proposed in the present work, increases the residence time of water in
the collector. It also increases the outlet temperature. Hence, the developed FPC model may be
considered as an alternative solution for growing thermophilic bacteria during the anaerobic
digestion in biogas production.