محمد أحمد السيد قاسم
أستاذ
Voltammetric Analysis of Diaveridine at Electrochemically Pretreated Ultrafine Urethane Electrode
Current Physical Chemistry • 2017
معلومات البحث
المؤلفون
Mohammed A. Kassem; Moataz Morad; and M. I. Awad
الكلمات المفتاحية
Diaveridine HCl, Ultrafine Urethane Electrode, Cyclic Voltammetry, Electroanalysis, Square
Wave Voltammetry, Activation Potential.
المجلة العلمية
Current Physical Chemistry
الناشر
Benthamscience
المجلد
7
العدد
Not Available
الصفحات
Not Available
publication.type
International
رابط البحث
Not Available
المواد المرفقة
Not Available
الملخص
Background: The advanced veterinary medical care promotes improved health in
animals and allows for enhanced efficiency in animal husbandry. Drugs are stored in tissue
and can be ingested by humans, after being used in feeds and premixes to prevent various
intestinal disorders.
Objective: Diaveridine HCl (DVD), diaminopyimidine antimicrobial agent, has been
electroanalyzed at electrochemically activated ultrafine urethane (UT) electrode using square
wave voltammetry with well-known high sensitivity.
Method: The optimum conditions for electrochemical activation of UT electrode have been
explored. The effects of electrolyte pH and instrumental parameters on the electrochemical
behavior of DVD are optimized.
Results: At the optimum conditions, the rectilinear range for the DVD analysis was
constructed and found to extend over the range 1.68-16.4 µM. Both relative standard
deviation and confidence limit for six replicate measurements were calculated.
Conclusion: The electrochemical pre-treatment of UT via cycling of electrode in the
potential range -0.2-1.9 V was found to be the optimum; the maximum negative potential
shift with the larger peak current was obtained at the modified electrode at the optimum pH
(8.3)
animals and allows for enhanced efficiency in animal husbandry. Drugs are stored in tissue
and can be ingested by humans, after being used in feeds and premixes to prevent various
intestinal disorders.
Objective: Diaveridine HCl (DVD), diaminopyimidine antimicrobial agent, has been
electroanalyzed at electrochemically activated ultrafine urethane (UT) electrode using square
wave voltammetry with well-known high sensitivity.
Method: The optimum conditions for electrochemical activation of UT electrode have been
explored. The effects of electrolyte pH and instrumental parameters on the electrochemical
behavior of DVD are optimized.
Results: At the optimum conditions, the rectilinear range for the DVD analysis was
constructed and found to extend over the range 1.68-16.4 µM. Both relative standard
deviation and confidence limit for six replicate measurements were calculated.
Conclusion: The electrochemical pre-treatment of UT via cycling of electrode in the
potential range -0.2-1.9 V was found to be the optimum; the maximum negative potential
shift with the larger peak current was obtained at the modified electrode at the optimum pH
(8.3)
