Wael Salah Mansour Abdelrahman Mansour
Asst. Lecturer
Thermal performance optimization of parametric building envelope based on bio-mimetic inspiration
Ain Shams Engineering Journal, Science Direct • 2021
Publication Information
Authors
Wael Salah Mansour
Keywords
Thermal performance; Building envelope; Bio-mimicry; Inspiration; Optimization;
Genetic algorithms
Journal
Ain Shams Engineering Journal, Science Direct
Publisher
Science Direct, Elsevier
Volume
12
Issue
1
Pages
1133-1142
publication.type
International
Paper Link
Open Link
Supplementary Materials
Not Available
Abstract
Thermal performance of building envelope is acquired a great deal of global interest. Recently,
algorithms are used in architecture for generating inspired shapes from nature which could
effect on thermal performance. The research investigates an architectural design Methodology
based on a “Modeling-Simulation-Optimization” framework to control the thermal performance
of the building envelope. The design of a parametric building envelope is optimized by
biomimetic algorithms such as genetic algorithms to minimize the thermal performance. It
explores the possibilities of Enhancing the thermal performance of the building envelope by
reducing the total thermal loads of a proposed unit in an office building. Results demonstrate
that the total thermal loads are decreased from 366.36 KWh to 319.98 KWh which is about 12.65%
less than the total thermal loads of the default state before the optimization process. Finally,
possible configurations of the building envelope are presented to enhance thermal performance
in real architectural design.
algorithms are used in architecture for generating inspired shapes from nature which could
effect on thermal performance. The research investigates an architectural design Methodology
based on a “Modeling-Simulation-Optimization” framework to control the thermal performance
of the building envelope. The design of a parametric building envelope is optimized by
biomimetic algorithms such as genetic algorithms to minimize the thermal performance. It
explores the possibilities of Enhancing the thermal performance of the building envelope by
reducing the total thermal loads of a proposed unit in an office building. Results demonstrate
that the total thermal loads are decreased from 366.36 KWh to 319.98 KWh which is about 12.65%
less than the total thermal loads of the default state before the optimization process. Finally,
possible configurations of the building envelope are presented to enhance thermal performance
in real architectural design.